Fire-rated modular cable transit sealed through a concrete wall

Partner system · ST120 + ST240

Fire-rated cable transits you can re-enter

Certified service transits for data centres and critical facilities. The hinged casing retrofits around services that are already installed—add, remove or re-route through a fire barrier without break-out and without recertifying the penetration.

Up to 4 h integrity (E 240)EN 1366-3 · EN 13501-2CE + UKCA · ETA 21/0207

Why re-enterable

Protect the opening without losing future flexibility.

Every mastic-sealed penetration becomes a problem the day the cabling changes. A Firebreak transit is a permanent, certified opening in the fire barrier—engineered to be opened and closed for the life of the building. Pyralta checks every proposed construction against the certified scope before order.

01

Retrofit around live services

The powder-coated casing is hinged: it opens and closes around cables that are already installed. No disconnection, no downtime—then re-enter it whenever the cabling changes.

02

A dry system

Foam plugs restrict the passage of cold smoke day to day; under fire the intumescent core expands into a dense block of fire-resistant char. No wet trades, no curing, no routine maintenance.

03

Cables, baskets and pipes

Tested with electrical cables to 80 mm, telecoms bundles to 100 mm, unsheathed wire, steel cable baskets, PVC pipe to 82 mm and insulated copper and steel pipe to 90 mm.

04

Supplied and installed

One accountable route: engineering review, supply, certified installation in light partitions, and surveyed works in concrete and floors—with per-unit rates and photo evidence.

E 240Integrity, up to 240 minutesEI 180 insulation

1100×125Largest rectangular formatTakes 2 × 500 mm baskets

Y₂Durability classEAD 350454-00-1104

The range

Choose your transit family.

All devices are 254 mm deep, re-enterable, and supplied as a complete set with the corresponding mounting-flange set. Project pricing from 30 units.

Square 102 × 102 mm Firebreak Service Transit with galvanised steel mounting flange
ST120 SQUARE1–6 grouped

Square 102 × 102 mm

For cable bundles and mixed routes. Flange sets for one to six grouped transits in a single opening; 65 × 65 mm available on request.

  • Single, duplex, triplex, quadplex, sixplex flanges
  • Cables to 80 mm Ø, telecoms bundles to 100 mm
  • Walls ≥100 mm and concrete floors ≥150 mm
Complete set from€ 159 ex VAT
Request pricing ↗
Round Ø100 mm Firebreak Service Transit with circular mounting flange
ST120 ROUNDØ 50 / 100 / 150

Round Ø 50 / 100 / 150 mm

For single cables, smaller bundles and conduits, with circular mounting-flange sets on both faces.

  • Three standard diameters
  • Circular galvanised flange sets
  • Walls ≥100 mm and concrete floors ≥150 mm
Complete set from€ 115 ex VAT
Request pricing ↗
Large-format ST240 Firebreak Service Transit sized for two cable baskets side by side
ST240 LARGE250–1100 mm

Large format 250–1100 mm

For cable trays and high-density routes. The 1100 mm device takes two 500 mm wide baskets side by side; bespoke widths 550–1100 mm on request.

  • 250, 350, 450, 550 and 1100 mm × 125 mm
  • Steel cable baskets within the tested scope
  • Bespoke widths to project requirement
Complete set from€ 429 ex VAT
Request pricing ↗

Prices are indicative list prices per complete set, excluding VAT and delivery, valid through 31 December 2026. Project pricing applies from 30 units.

Specifications

At a glance.

Tested fire performance (EN 1366-3)

Headline values from the PYRALTA technical data sheet, edition 01 · 08/26 (based on manufacturer TDS Issue 04, 12/25). The exact classification for a penetration depends on the service, cable type per EN 1366-3 Annex A, loading, insulation and whether Insulwrap protection is applied. Pyralta confirms the applicable classified system per opening before order, free of charge.
ConstructionPenetrating servicesIntegrity (E)Integrity & insulation (EI)
Walls ≥100 mm
dry line, concrete block or masonry
Electrical cables to 80 mm Ø, telecoms bundles to 100 mm Ø, unsheathed wire to 24 mm Øup to E 120up to EI 120
with Insulwrap protection
Concrete floors ≥150 mmCables, telecoms bundles, steel cable basketsup to E 240up to EI 180
Walls ≥100 mm — pipes
concrete block or masonry
PVC to 82 mm; copper/steel to 42 mm; steel to 90 mm, with continuous K-Flex ST or Armaflex insulationup to E 240up to EI 180
Concrete floors ≥150 mm — pipesPVC to 82 mm; steel to 90 mm with continuous insulationup to E 180up to EI 120
!

Technical qualificationRatings vary by substrate, orientation, transit size, services, insulation and configuration. The highest tested values are E 240 (integrity) and EI 180 (integrity and insulation), and they do not occur in the same configuration.

Documentation & compliance

Everything your fire engineer, building control or insurer will ask for.

One click, no registration. Publishing the Declarations of Performance un-gated is a CPR requirement, not a marketing choice.

Technical data

PYRALTA technical data sheet, edition 01 · 08/26: tested-performance tables per construction, cable type definitions per EN 1366-3 Annex A, dimensions and installation method. The manufacturer sheet remains the source document.

Declarations of Performance

DoP under the Construction Products Regulation for the EU (CE) market and a UKCA DoP for the United Kingdom, both against ETA 21/0207 and EAD 350454-00-1104.

Certificates & safety

UL International certificate UL-EU-00772, the manufacturer product data sheet and the safety data sheet (01/25). Consult the SDS before use.

01

Installed correctly

Engineered into the barrier, documented for the auditor.

  • Light partitions: flanges both faces, perimeter sealed
  • Concrete and masonry: surveyed, scanned, core or saw cut
  • Traceability label per transit
  • Completion photograph per opening
02

Evidence

UL-EU Certificate UL-EU-00772 identifies the assessed product scope.

  • EAD 350454-00-1104
  • Classification to EN 13501-2
  • Test data to EN 1366-3
  • Wall and concrete-floor uses
01

Review

Send drawings, photographs or a quantities list. We review the barriers, the services and the required ratings.

02

Engineer

We select the tested configuration per penetration and confirm the applicable classification.

03

Supply

Complete sets delivered boxed and labelled per opening—or timed, secured delivery for live sites.

04

Verify

Certified installation with per-unit rates, photo evidence and traceability labels for your fire file.

Built for live data centres

Moves, adds and changes without hot work.

Re-enter the transit instead of re-drilling the slab. Install transits empty as certified blank seals during fit-out, and pull cables through years later with no firestopping works at all.

  1. 01

    Grouped duplex-to-sixplex openings keep walls tidy and inspectable

  2. 02

    The largest ST240 takes two 500 mm cable baskets side by side

  3. 03

    Timed, security-cleared deliveries and inducted installation crews

Also for battery rooms

Service penetrations into battery storage and charging rooms carry the same compartmentation duty. Combine transits with certified containment for the batteries themselves.

Lithium battery storage ↗

Questions

Frequently asked.

What fire rating do Firebreak Service Transits achieve?
Up to E 240 for integrity and up to EI 180 for integrity with insulation, depending on the tested construction, service type, cable loading, insulation and installation configuration. Systems are tested to EN 1366-3 and classified to EN 13501-2, with ETA 21/0207 and UL International certificate UL-EU-00772. Note that the manufacturer summary sheet states “up to 4 hours (EI240)”, but no table in the technical data sheet or the UL certificate scope shows an EI value above 180—the 240-minute figures are integrity (E). Our engineers confirm the applicable classified system for your exact barrier before order.
Can cables be added after installation?
Yes—that is the point. Open the device, route the new cables through the intumescent cushions and close it again. The certified seal is restored without break-out and without recertifying the penetration.
Can it be fitted around cables that are already installed?
Yes. The casing is hinged: open the lid, fit the transit around the existing services, close it and refit the foam plugs. No disconnection of live services is required, which suits remediation and retrofit work in operational buildings.
Does it work for pipes as well as cables?
Yes—tested with PVC pipe up to 82 mm, and copper and steel pipes up to 90 mm with continuous K-Flex ST or Armaflex insulation, reaching up to E 240 / EI 180 depending on the construction. The technical data sheet carries the full pipe tables.
What is included in a complete set?
One transit device plus the corresponding mounting-flange set. Spare and grouped flange sets—duplex, triplex, quadplex and sixplex for the 102 mm and 65 mm square transits—are listed separately.
Can transits be installed empty, for future capacity?
Yes. A closed transit is a certified blank penetration seal. Many data centres install spare transits during fit-out; when new cables are needed years later they are simply pulled through the cushions, with no wet trades, no specialist labour and no new certification.
Do you install?
Yes. Light-partition installation is priced per unit and includes opening formation, complete installation with flanges on both faces, perimeter sealing, a traceability label and photo evidence. Concrete, masonry and floors are quoted after survey.
Are bespoke sizes available?
ST240 large transits are available in bespoke widths between 550 and 1100 mm on request, and the square device is also available in 65 × 65 mm.
Is the system compliant for the UK as well as the EU?
Yes. The product carries a CE marking under the CPR and a UKCA Declaration of Performance, plus UL International certification UL-EU-00772, so one system covers EU, UK and international specifications.

Pricing & engineering review

Send quantities or drawings—not a product code.

You will receive either a priced offer or a short list of questions from an engineer. Not a brochure.

  • Response within one working day
  • Offices in Barcelona and Rotterdam
  • Supply only, or supplied and installed
↳

Secure project intakeThis review prepares your technical brief without asking for confidential project files. Secure document exchange is arranged after qualification.

We use these details only to answer your request. See the contact page for our office details.